New Software Version: TestUp V62

The new TestUP version 62 is available for download in the Downloads section of the website. Continue reading for the changes we have made.

TESTS

  • New test of shock accelerometer calibration has been added. It allows getting amplitude characteristic of an accelerometer using a drop shock machine. The feature completes the accelerometer calibration modules set in the software and allows making complete calibration of an accelerometer within one software.                                                                                                                                                                                                                                                                                                                                                                             

FEATURES

  • Feature of running two or more copies of the program has been added (one of the copies can be used for running a test, other for viewing results. Graph lines can be copied from one instance of the program to another);

  • Simplified interface mode has been added to Sine, Random, Shock tests;

  • A feature of continuation of a test after changing some fields on the Control tab;
  • The new setup wizard, allowing customizing all the crucial settings before using the program, has been added.

IMPROVEMENTS 

  • Default report settings has been changed accordingly to the customer requests;
  • A vaufx file can be exported to Mat5 и Mat7.4. formats;
  • Filtration feature has been added to the sensors database;

 

  • Ribbon can now be configured via the corresponding menu. 

GRAPHS

  • Graph settings window has been completely rewritten for more convenience;

  • Added cursor to calculate minimum and maximum for graph lines in the specified range; 

  • Menu item for deleting user defined points has been added;

  • Abort and tolerance lines now can be copied and pasted;
  • Several graph lines can be copied and pasted simultaneously;
  • Resonance can be searched via context menu (works if a real device is connected only).

 

SINE

  • Resonance search method which looks for crossing zero of real part of FRF has been added;
  • Resonance dwell can be saved for continuation.

FATIGUE 

  • Resonance search method which looks for crossing zero of real part of FRF has been added;
  • Estimated, total and left time now are calculated for the resonance work-off.

SHOCK

  • Graph mode, where pulse begins at zero has been added.

SROR 

  • Added panel for displaying SoR tones amplitude on channels;

  • Added graphs for displaying SoR tone amplitude on channels;  
     

SHAKER VERIFICATION

  • Channels now can be inverted.

MULTISHAKER SROR 

  • Added panel for displaying SoR tones amplitude on channels;
  • Added graphs for displaying SoR tone amplitude on channels.

TRANSIENT CAPTURE 

  • A feature for specifying zero level has been added (crucial for low-level shocks);

  • Added feature of calculating main frequency of the captured shock;
  • Added a new report mode, which allows writing in report only shocks outside specified range.

 
ACCELEROMETER CALIBRATION 

  • A feature to change part of an octave in the database has been added;
  • A feature to view work/reference accelerometer ratio has been added;
  • A feature to change units of environment parameters(temperature, humidity, pressure) has been added. 

The new vibration test software TestUP version 60 is available for download in the Downloads section of the website.

For more information about our vibration testing software, contact us through email or phone: +371 6610 2166.

We care about your budget — software updates are free for all our users.