DAQ system and spectrum analyzer is intended for measuring, registering and analyzing vibration data and other physical processes.

RL-R19 enables the user to:

  • acquire and transfer data from vibration sensors;
  • examine the vibration condition of machines, mechanisms, mechanical constructions, bearings, gearings etc. detect various;
  • defects of machines, mechanisms, mechanical constructions, bearings, gearings etc.;
  • balance rotors of machines and mechanisms.

The principle of building up the software of RL-R19 devices enables forming a set of functional options intended to solve specific problems.

The only obligatory option is “Basic Software”, other options may be combined in any configuration.

The following options are available:

  • Basic software (including making and viewing recordings).
  • Part-octave analysis.
  • Statistic analysis.
  • Balancing.
  • Signal generator.
  • Repeater.
  • Automatic measurements.
  • Filtration.
  • Shock analysis.
  • Synchronization.

Specifikācija

Number of measuring channels
4÷8
Tacho-channel
1
Range of measure signals
±20 V
Mode of measuring channels
IEPE, linear, single-ended
Logical inputs and outputs
4 inputs and 4 outputs
Screen resolution
640×480 pixels
Screen diagonal
5.7 inches
Battery capacity
≥ 8000 mAh
Protection
IP65
Input
Input type / Sensor type
IEPE, linear
FRF non-linearity (1kHz) in the range of 1 ÷ 40000 Hz
≤ 2 dB
FRF non-linearity (1kHz) in the range of 1 ÷ 60000 Hz
≤ 5 dB
Other
Frequency range
DC, 0.1÷60000 Hz
DAC/ADC resolution
24 bits
Temperature range
-30 ÷ +60 °C
Dimensions
260×152×55 mm
Weight
2.3 kg
Power supply
Autonomous (> 8 hours) 230 V AC 12-36 V DC V

Programmas interfeiss

SignalUP. Signal view
SignalUP. Spectrum
SignalUP. File editor
SignalUP. Filtering
SignalUP. Statistical analysis
SignalUP. Waterfall Analysis

Biežāk uzdotie jautājumi (BUJ)

Can I reproduce a recording made on RL-R19 on a different RULA device?

Yes, you can reproduce them on RL-R19, RL-C21 or RL-C25.

Can I connect a gauge sensor to RL-R19?

You cannot do it directly. However, it can be done using a signal conditioner.

Skatīt vairāk (BUJ)
Can I use a different microSD-card with my RL-R19 (not from the delivery set)?

Yes, it is possible. To do that, copy all the files and folders (except for “User Data”) from the root folder of the SD-card. The new SD-card must be rated to 45MB/s write speed.

Why does the message “TM” appears on the screen instead of the measurement result?

This message is shown in case there is an issue with the signal from the tachometric sensor. Check that:

  1. The tachometric sensor is connected to Channel 9 of the device.
  2. Channel 9 is enabled in the channel settings.
  3. Power is supplied to the tachometric sensor (if necessary).
  4. There is an optical mark in the sensor FOV the sensor, to which it reacts.
  5. The size of the mark and the distances between it and the sensor are such that the sensor can detect it.
  6. No source of bright light is directed to the sensor.

Informācija Par Produktu