The software module provides traceable back-to-back calibration of accelerometers, velocity, displacement, and vibration sensors according to ISO 16063-21 and boasts advanced technical capabilities:

  • User-defined stepped Sine profile
  • Calibration by substitution method
  • Triaxial measurements in one protocol
  • Transverse sensitivity test
  • Calibration in manual mode
  • Calibration using Random signal

Get in touch to schedule an online demonstration <<

Specialized software

Automated Procedure

RULA software provides a convenient way to calibrate your sensors:

  • input the reference sensor data
  • input the sensor under calibration data
  • choose the algorithm and needed frequencies
  • start calibrating!

The module automatically generates a detailed report for every calibrated sensor. 

Shorter Calibration Time

RULA software provides a convenient way to calibrate your sensors:

  • input the reference sensor data
  • input the sensor under calibration data
  • choose the algorithm and needed frequencies
  • start calibrating!

The module automatically generates a detailed report for every calibrated sensor. 

Specifikācija

Calibration frequency range
0.1÷35 kHz for RL-C21
DC÷80 kHz for RL-C21M
0.1÷106 kHz for RL-C25
Calibration by substitution
Supported
Calibration using random signal
Supported
Supported TEDS templates
25
Calibration time in random signal mode
< 3 min

Features

RULA software module combines all features necessary for precise quick and convenient calibration:

  • Choose between Sine and Random algorithms for your task;
  • Connect multiple shakers to cover a large frequency range;
  • Employ our database set up to save and switch between sensor and shaker configurations;
  • Customize conditions and characteristics of all parts of the calibration system.
Automated reports
Automated reports

After any calibration procedure, TestUP automatically creates a comprehensive report, which includes:

  • measurement results in the form of tables and graphs;
  • detailed information about the reference sensor;
  • calibration date and time, etc.

Calibration Standards Compliance

Calibration is a strictly standardized procedure. Our software is made according to the most recognizable standards:

  • ISO 16063-1:1998 Methods for the calibration of vibration and shock transducers — Part 1: Basic concepts
  • ISO 16063-21:2003 Methods for the calibration of vibration and shock transducers — Part 21: Vibration calibration by comparison to a reference transducer
  • ISO 16063-31:2009 Methods for the calibration of vibration and shock transducers — Part 31: Testing of transverse vibration sensitivity
Calibration Standards Compliance
Intuitive & Flexible UI
Research and Development

Besides the automated measurements, a manual measurement mode is implemented in RULA software.


The mode allows you to specify the frequency and amplitude (in acceleration, velocity, or displacement units) manually and check the response from the sensors. It is highly useful for research purposes and is a great choice for laboratories and research centers.

Intuitive & Flexible UI
Intuitive & Flexible UI

The calibration module has a user-friendly interface and supports databases and importing/exporting data from files for quick and convenient access to sensor and shaker configurations. 

Save your system data and switch between different profiles on the fly.

Rich customization options inside the module allow you to fine-tune the settings to suit your task.

Programmas interfeiss

Informācija Par Produktu

Sensor Calibration

Programmatūras Versijas

Citas iekārtas